Point-of-care and dried-blood-spot HCV RNA testing: finger-stick Xpert assay sensitivity 99% / specificity 99% for detection (7 studies, 987 samples); dried blood spots sensitivity 97% / specificity 100% (28 studies, 3,988 samples)

Shelf #9880 · Critical care & sepsis

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately do point-of-care finger-stick assays and dried blood spot samples detect and quantify hepatitis C virus RNA, against venous-blood laboratory testing?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: 1 systematic review of 43 studies of point-of-care and dried-blood-spot (DBS) HCV RNA assays (Catlett 2022). Sensitivity and specificity are labelled in words wherever they appear on this shelf. Accuracy was excellent in the pool: the finger-stick Xpert HCV Viral Load Fingerstick assay (the tested product named in the record, a Cepheid assay — named here under the tested-product clarification, as the record names it) gave sensitivity 99% and specificity 99% for RNA detection across 7 studies with 987 samples, and DBS gave sensitivity 97% and specificity 100% across 28 studies with 3,988 samples. The operational caveat is printed on the card: 6% of finger-stick results were invalid. This shelf asks about detecting the virus itself (RNA): live #8602 asks about rapid antibody tests, which detect exposure rather than viraemia — a different analyte and a different question, fenced here. The stamp is held at PARTIAL despite the high pairs because the evidence is a single synthesis of assay-comparison studies, several limbs rest on few studies, and the invalid-result rate is part of real-world accuracy. MEASUREMENT ACCURACY — PARTIAL: one accuracy synthesis, Tier C by rule for accuracy shelves.

MeSH: Dried Blood Spot Testing · Hepacivirus · Hepatitis C · Humans · Point-of-Care Testing · RNA, Viral · Sensitivity and Specificity · Viral Load

Cards (2)

Card 1 — Catlett 2022 (43 studies): finger-stick point-of-care HCV RNA sensitivity 99% / specificity 99% (987 samples) with 6% invalid results; DBS sensitivity 97% / specificity 100% (3,988 samples)

Study: Systematic review (accuracy; 43 studies)

Population: Systematic review of 43 eligible studies of point-of-care testing and dried blood spot samples for determination of HCV RNA, identified from 359 articles across bibliographic databases and conference presentations; meta-analysis used to pool estimates. Registry ID: not stated in the record.

Summary: Catlett 2022 (43 studies): finger-stick point-of-care HCV RNA sensitivity 99% / specificity 99% (987 samples) with 6% invalid results; DBS sensitivity 97% / specificity 100% (3,988 samples)

Result: For the Xpert HCV Viral Load Fingerstick assay against venous blood samples (7 studies with 987 samples), sensitivity and specificity for HCV RNA detection were 99% (95% CI 97% to 99%) and 99% (95% CI 94% to 100%), and for HCV RNA quantification 100% (95% CI 93% to 100%) and 100% (95% CI 94% to 100%). The proportion of invalid results following finger-stick testing was 6% (95% CI 3% to 11%). For dried blood spot samples against venous blood (28 studies with 3,988 samples), sensitivity and specificity for detection were 97% (95% CI 95% to 98%) and 100% (95% CI 98% to 100%), and for quantification 98% (95% CI 96% to 99%) and 100% (95% CI 95% to 100%). The authors conclude excellent diagnostic accuracy was observed across assays for detection of HCV RNA from finger-stick and DBS samples, and that the invalid-result proportion highlights the importance of operator training and quality-assurance programmes.

Watch out: The 6% invalid rate is not in the sensitivity/specificity pairs — in field use roughly 1 in 17 finger-stick tests returned no result at all, which is an accuracy-relevant failure the pooled pairs hide. Quantification limbs (100% / 100%) rest on fewer samples than the detection limbs, as their wider intervals show.

Source: Catlett B, Hajarizadeh B, Cunningham E, Wolfson-Stofko B et al. Diagnostic Accuracy of Assays Using Point-of-Care Testing or Dried Blood Spot Samples for the Determination of Hepatitis C Virus RNA: A Systematic Review. Journal of Infectious Diseases. 2022. PMID: 35150578. Registry ID: not stated in the record. MeSH: Dried Blood Spot Testing · Hepacivirus · Hepatitis C · Humans · Point-of-Care Testing · RNA, Viral · Sensitivity and Specificity · Viral Load

Card 2 — Synthesis — HCV RNA can be detected accurately from a finger-stick or a dried spot; the remaining accuracy problem is operational, not analytic

Study: Synthesis

Population: Synthesis of the single review carded on this shelf (43 studies; 987 finger-stick samples and 3,988 DBS samples in the pooled limbs, overlapping study sets kept as the record states them); no additional source.

Summary: Synthesis — HCV RNA can be detected accurately from a finger-stick or a dried spot; the remaining accuracy problem is operational, not analytic

Result: Detection accuracy for both specimen routes sits at sensitivity 97–99% and specificity 99–100% against venous laboratory testing, so a positive point-of-care RNA result identifies current infection — the step antibody tests (live #8602) cannot take, since antibody marks exposure, not viraemia. The qualifications are the 6% invalid rate and the review's own emphasis on operator training and quality assurance. Tier C by rule for accuracy shelves.

Watch out: Documented evidence is one 2022 synthesis; assay generations after its search are not evaluated in the carded record, and no figure for any later platform is printed. The Xpert assay is named as the record names it; no other brand-level pool is given in the record.

Source: Synthesis of the carded record above (PMID: 35150578). Registry ID: not stated in the record.