SourceMed · Shelf #9888 in the ask interface

Urinary antigen tests for Legionella and pneumococcal pneumonia (documented N = 12,366 patients in the pneumococcal meta-analysis; the Legionella synthesis pools 30 studies): pneumococcal sensitivity 0.66 / specificity 0.90, Legionella sensitivity 0.74 / specificity 0.991

Shelf #9888 · Critical care & sepsis

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2009–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately do urinary antigen tests detect Legionella and Streptococcus pneumoniae infection in patients with suspected pneumonia — what pooled sensitivity and specificity (labelled in words) do the meta-analyses find against culture and other reference standards, and how much does the imperfect reference standard move the pneumococcal estimates?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: 1 meta-analysis of Legionella urinary antigen (30 studies; Shimada 2009), 1 meta-analysis of pneumococcal urinary antigen in 12,366 patients with suspected pneumonia and acute respiratory failure (30 studies, 1,548 with the target condition; Yasuo 2022), and 1 Bayesian latent-class meta-analysis of the BinaxNOW pneumococcal urinary antigen test that adjusts for the imperfect accuracy of culture (Xie 2017). Sensitivity and specificity are labelled in words at first occurrence on this shelf: for Legionella (almost entirely serogroup 1), pooled sensitivity was 0.74 (95% CI 0.68 to 0.81) and pooled specificity was 0.991 (95% CI 0.984 to 0.997) (Shimada 2009). For pneumococcal pneumonia, pooled sensitivity was 0.66 (95% CI 0.62 to 0.69) and pooled specificity was 0.90 (95% CI 0.85 to 0.93) against culture or smear references (Yasuo 2022); when the reference culture's own imperfection was modelled, the same test's pooled sensitivity was 0.74 (95% credible interval 0.67 to 0.83) and specificity 0.96 (0.92 to 0.99) (Xie 2017). MEASUREMENT ACCURACY — PARTIAL: both tests are highly specific and only moderately sensitive — a positive result is strong evidence, a negative result misses roughly a quarter to a third of cases — and the Legionella pool's own authors warn its study quality was low with evidence of publication bias.

MeSH: Antigens, Bacterial · Humans · Legionella · Legionellosis · Sensitivity and Specificity · Urinalysis · Adult · Pneumonia, Pneumococcal · Prospective Studies · Respiratory Distress Syndrome · Respiratory Insufficiency · Retrospective Studies · Streptococcus pneumoniae · Bayes Theorem · Cost-Benefit Analysis · Diagnostic Test Approval · Reagent Kits, Diagnostic · Reference Standards · Reference Values

Cards (4)

Card 1 — Legionella urinary antigen, 30 studies: sensitivity 0.74, specificity 0.991 (Shimada 2009)

Study: Systematic review and meta-analysis (30 studies)

Population: Systematic review and meta-analysis of Legionella urinary antigen assays: 30 studies met inclusion criteria (40 assays reported; 26 commercial, 14 in-house), almost all focused on serogroup 1 Legionella, against described reference standards; quality assessed with QUADAS.

Summary: Legionella urinary antigen, 30 studies: sensitivity 0.74, specificity 0.991 (Shimada 2009)

Result: Sensitivity (labelled in words at first occurrence on this shelf) pooled at 0.74 (95% CI 0.68 to 0.81) and specificity at 0.991 (95% CI 0.984 to 0.997). Study quality was generally low (average QUADAS score 4.4 of 14, range 1 to 9), higher-quality studies had lower sensitivity, and there was evidence of publication bias — the authors conclude the pooled performance probably overestimates the test's accuracy.

Watch out: The pool is a serogroup-1 test in practice: performance against other Legionella serogroups and species is barely represented, and the authors' own quality warning applies to the headline pair.

Source: Shimada T, Noguchi Y, Jackson JL et al.. Systematic review and metaanalysis: urinary antigen tests for Legionellosis. Chest. 2009. PMID: 19318671. Registry ID: not stated in the record. MeSH: Antigens, Bacterial · Humans · Legionella · Legionellosis · Sensitivity and Specificity · Urinalysis

Card 2 — Pneumococcal urinary antigen, 12,366 patients: sensitivity 0.66, specificity 0.90 (Yasuo 2022)

Study: Systematic review and meta-analysis (30 studies, 12,366 patients)

Population: Systematic review and meta-analysis of urinary antigen tests for Streptococcus pneumoniae in adult patients with clinically diagnosed pneumonia and acute respiratory failure: 30 studies, 12,366 patients including 1,548 (12.5%) with the target condition, against culture or smear references; bivariate random-effects model; QUADAS-2 quality rated serious overall.

Summary: Pneumococcal urinary antigen, 12,366 patients: sensitivity 0.66, specificity 0.90 (Yasuo 2022)

Result: Pooled sensitivity was 0.66 (95% CI 0.62 to 0.69) and pooled specificity was 0.90 (95% CI 0.85 to 0.93). The authors conclude the test is useful for achieving a definitive diagnosis of pneumococcal infection in patients with pneumonia — a rule-in profile, with about one in three true cases testing negative.

Watch out: The population is pneumonia with acute respiratory failure — a sicker spectrum than general community-acquired pneumonia — and the reference (culture or smear) is itself imperfect, which is the subject of the next card.

Source: Yasuo S, Murata M, Nakagawa N et al.. Diagnostic accuracy of urinary antigen tests for pneumococcal pneumonia among patients with acute respiratory failure suspected pneumonia: a systematic review and meta-analysis. BMJ open. 2022. PMID: 35953247. Registry ID: not stated in the record. MeSH: Adult · Humans · Pneumonia, Pneumococcal · Prospective Studies · Respiratory Distress Syndrome · Respiratory Insufficiency · Retrospective Studies · Sensitivity and Specificity · Streptococcus pneumoniae

Card 3 — Adjusting for imperfect culture moves BinaxNOW pneumococcal antigen to sensitivity 0.74, specificity 0.96 (Xie 2017)

Study: Latent-class meta-analysis (BinaxNOW-SP)

Population: Bayesian latent-class meta-analysis of the BinaxNOW Streptococcus pneumoniae urinary antigen test (named as published), modelling the inaccuracy of standard culture instead of treating it as a perfect reference; combined with prevalence data to estimate correctly classified cases and the cost of adding the test.

Summary: Adjusting for imperfect culture moves BinaxNOW pneumococcal antigen to sensitivity 0.74, specificity 0.96 (Xie 2017)

Result: The BinaxNOW-SP test had a pooled sensitivity of 0.74 (95% credible interval 0.67 to 0.83) and a pooled specificity of 0.96 (95% credible interval 0.92 to 0.99) after adjustment for imperfect culture. Adding the test to standard cultures increased overall diagnostic accuracy by 6.2%, at an incremental cost of $582 Canadian dollars per additional case correctly classified.

Watch out: These are model-adjusted estimates, not a recount: they answer 'how accurate is the test if culture also errs?' and are not interchangeable with the conventional pair in the previous card — the gap between the two pairs is itself the finding.

Source: Xie X, Sinclair A, Dendukuri N. Evaluating the accuracy and economic value of a new test in the absence of a perfect reference test. Research synthesis methods. 2017. PMID: 28544646. Registry ID: not stated in the record. MeSH: Antigens, Bacterial · Bayes Theorem · Cost-Benefit Analysis · Diagnostic Test Approval · Humans · Pneumonia, Pneumococcal · Reagent Kits, Diagnostic · Reference Standards · Reference Values · Sensitivity and Specificity

Card 4 — Synthesis — specific enough to rule in, too insensitive to rule out

Study: Synthesis

Population: Synthesis of the three carded records; no additional source.

Summary: Synthesis — specific enough to rule in, too insensitive to rule out

Result: Across both organisms the pattern is the same: specificity is high (0.90–0.96 for pneumococcal antigen depending on the reference handling; 0.991 for Legionella serogroup 1) while sensitivity is moderate (0.66–0.74), so a positive urinary antigen is strong evidence and a negative one leaves roughly a quarter to a third of infections undetected. The pneumococcal pair moves materially (0.66/0.90 to 0.74/0.96) when the reference standard's own errors are modelled.

Watch out: Boundary: Legionella PCR and direct fluorescent antibody accuracy appear inside the wider diagnostic-test literature (Cristovam 2017 was screened and not carded — its pooled analysis covers PCR and DFA, not the urinary antigen) and pneumonia treatment shelves are different questions — this shelf owns only the urinary antigen tests.

Source: Synthesis of the carded records above (PMIDs 19318671, 35953247, 28544646). Registry ID: not stated in the records.