Dried blood and plasma spot specimens for HIV-1 viral load (documented N = 10,871 paired dried-blood-spot samples and 1,847 paired dried-plasma-spot samples): at the 1,000 copies/mL treatment-failure threshold most technologies exceed sensitivity 95%, but specificity ranges from above 85% to below 60% by technology
Shelf #9890 · Critical care & sepsis
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 1999–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately do dried blood spot and dried plasma spot specimens measure HIV-1 viral load against liquid plasma — what bias, sensitivity and specificity (labelled in words) do the meta-analyses find at the World Health Organization 1,000 copies/mL treatment-failure threshold, and how much does performance vary between testing technologies?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: 2 systematic reviews with meta-analysis of paired dried-spot versus plasma specimens (dried blood spots: 40 studies, 10,871 paired data points, Vojnov 2022; dried plasma spots: 16 studies in the meta-analysis, 1,847 paired data points, Fong 2022). Sensitivity and specificity are labelled in words at first occurrence on this shelf. Dried blood spot specimens produced consistently higher mean viral loads than plasma, yet at the 1,000 copies/mL treatment-failure threshold each technology compared best to plasma: 5 technologies had sensitivity greater than 95%, 5 had specificity greater than 85%, but 2 technologies had specificity less than 60% at that threshold (Vojnov 2022). Dried plasma spots showed a mean bias of 0.28 log10 copies/mL, with sensitivity and specificity greater than 92% across all treatment-failure thresholds analysed and total misclassification below 5.4% (Fong 2022). MEASUREMENT ACCURACY — PARTIAL: dried spots classify treatment failure well at the 1,000 copies/mL threshold for most technologies, but performance is technology-specific — two dried-blood-spot technologies misclassify often enough (specificity below 60%) that the specimen type alone does not guarantee accuracy.
MeSH: Dried Blood Spot Testing · HIV Infections · HIV-1 · Humans · RNA, Viral · Sensitivity and Specificity · Viral Load · Treatment Failure
Cards (3)
Card 1 — Dried blood spots, 10,871 paired samples: sensitivity above 95% for 5 technologies at 1,000 copies/mL, specificity below 60% for 2 (Vojnov 2022)
Study: Systematic review and meta-analysis (40 studies, 10,871 paired samples)
Population: Systematic review and meta-analysis of paired dried blood spot and plasma HIV-1 viral load results: 60 studies identified (2007–2018), 40 included in the meta-analysis totalling 10,871 paired dried blood spot:plasma data points, analysed by testing technology with random-effects models.
Summary: Dried blood spots, 10,871 paired samples: sensitivity above 95% for 5 technologies at 1,000 copies/mL, specificity below 60% for 2 (Vojnov 2022)
Result: Sensitivity (labelled in words at first occurrence on this shelf) and specificity are technology-dependent: dried blood spot specimens produced consistently higher mean viral loads than plasma across all technologies, but at the 1,000 copies/mL treatment-failure threshold each technology compared best to plasma — 5 technologies had sensitivity greater than 95%, 5 technologies had specificity greater than 85%, yet 2 technologies had specificity less than 60% at that threshold. The authors note nearly all studies prepared dried spots in laboratories with precision pipetting, limiting direct applicability to field-prepared spots.
Watch out: The headline is a range across technologies, not a single pair: quoting 'sensitivity >95%' without the two technologies whose specificity fell below 60% would misstate the evidence.
Source: Vojnov L, Carmona S, Zeh C et al.. The performance of using dried blood spot specimens for HIV-1 viral load testing: A systematic review and meta-analysis. PLoS medicine. 2022. PMID: 35994520. Registry ID: not stated in the record. MeSH: Dried Blood Spot Testing · HIV Infections · HIV-1 · Humans · RNA, Viral · Sensitivity and Specificity · Viral Load
Card 2 — Dried plasma spots, 1,847 paired samples: sensitivity and specificity above 92% at every threshold, bias 0.28 log10 copies/mL (Fong 2022)
Study: Systematic review and meta-analysis (16 studies, 1,847 paired samples)
Population: Systematic review and meta-analysis of dried plasma spot versus liquid plasma HIV-1 viral load: 23 studies in the review, primary data from 16 studies (18 countries) in the meta-analysis, totalling 1,847 paired dried plasma spot:plasma data points.
Summary: Dried plasma spots, 1,847 paired samples: sensitivity and specificity above 92% at every threshold, bias 0.28 log10 copies/mL (Fong 2022)
Result: The mean bias of dried plasma spot specimens compared with plasma was 0.28 log10 copies/mL, and more dried plasma spot values were undetectable than plasma values (43.6% versus 29.8%). Analysing all technologies together, sensitivity and specificity were greater than 92% across all treatment-failure thresholds compared, with total misclassification below 5.4% across all thresholds; some individual technologies performed lower.
Watch out: Dried plasma spots are a different specimen from dried blood spots (the previous card): their cleaner pooled pair comes with a higher undetectable rate (43.6% versus 29.8%), so threshold classification and low-level detection are different questions.
Source: Fong Y, Markby J, Andreotti M et al.. Diagnostic Accuracy of Dried Plasma Spot Specimens for HIV-1 Viral Load Testing: A Systematic Review and Meta-analysis. Journal of acquired immune deficiency syndromes (1999). 2022. PMID: 34732684. Registry ID: not stated in the record. MeSH: Dried Blood Spot Testing · HIV Infections · HIV-1 · Humans · RNA, Viral · Sensitivity and Specificity · Treatment Failure · Viral Load
Card 3 — Synthesis — threshold classification is good; the technology, not the spot, decides
Study: Synthesis
Population: Synthesis of the two carded records; no additional source.
Summary: Synthesis — threshold classification is good; the technology, not the spot, decides
Result: Both dried specimens track plasma well enough to classify treatment failure at 1,000 copies/mL for most technologies (dried plasma spots: sensitivity and specificity above 92%, misclassification below 5.4%; dried blood spots: sensitivity above 95% for 5 technologies), while dried blood spots read systematically higher than plasma and two of their technologies fall below 60% specificity. Accuracy claims for 'dried spots' without a named technology overstate what the evidence supports.
Watch out: Boundary: antiretroviral treatment efficacy and HIV self-test accuracy (live #534, #8604) are different questions — this shelf owns only the dried-spot specimen's agreement with plasma viral load.
Source: Synthesis of the carded records above (PMIDs 35994520, 34732684). Registry ID: not stated in the records.