SourceMed · Shelf #9944 in the ask interface
Ruling out acute aortic syndromes with the ADD-RS plus D-dimer (ADvISED, documented N = 1,850): an ADD-RS of 0 or ≤1 with a negative D-dimer missed 0.3% of cases while ruling out 15.9% to 49.9% of suspected patients; D-dimer alone had sensitivity 96.7% / specificity 64%
Shelf #9944 · Heart, vessels, blood pressure & clotting
PREDICTIVE PERFORMANCE — PARTIAL
Stamped: 2026-11-28.
Evidence published: 2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In outpatients with symptoms compatible with an acute aortic syndrome in whom the diagnosis is being considered, how safely and efficiently does combining the aortic dissection detection risk score (ADD-RS) with D-dimer testing rule the diagnosis out — what are the failure rate and the proportion ruled out for ADD-RS = 0 with negative D-dimer and for ADD-RS ≤1 with negative D-dimer?
Balance of the evidence
PREDICTIVE PERFORMANCE — PARTIAL — Composition: 1 prospective multicentre diagnostic study (ADvISED, Nazerian 2018) in 1,850 outpatients with suspected acute aortic syndrome, of whom 241 (13%) had the condition — a documented base of 1,850 patients. Accuracy terms are labelled in words at first occurrence: D-dimer at a 500 ng/mL cutoff had sensitivity 96.7% (95% CI 93.6 to 98.6) and specificity 64% (95% CI 61.6 to 66.4) on its own, which is not enough to rule out alone. Combined strategies performed as follows: ADD-RS = 0 with negative D-dimer ruled out 294 patients (efficiency 15.9%) with 1 missed case (failure rate 0.3%, 95% CI 0.1 to 1.9); ADD-RS ≤1 with negative D-dimer ruled out 924 patients (efficiency 49.9%) with 3 missed cases (failure rate 0.3%, 95% CI 0.1 to 1). PREDICTIVE PERFORMANCE — PARTIAL: in this single prospective study the combined score-plus-D-dimer strategy missed about 3 in 1,000 ruled-out patients, but it is one study, in a population with a high 13% disease prevalence, and the wider (≤1) strategy's efficiency gain rests on the same single dataset.
MeSH: Acute Disease · Aged · Aortic Dissection · Aortic Aneurysm · Aortography · Biomarkers · Clinical Decision-Making · Computed Tomography Angiography · Decision Support Techniques · Diagnosis, Differential · Europe · Female · Fibrin Fibrinogen Degradation Products · Humans · Male · Middle Aged · Predictive Value of Tests · Prognosis · Prospective Studies · Reproducibility of Results · Syndrome
Cards (1)
Card 1 — ADvISED (Nazerian 2018): ADD-RS ≤1 plus negative D-dimer ruled out half of suspected patients and missed 3 of 924; D-dimer alone sensitivity 96.7% / specificity 64%
Study: Prospective diagnostic accuracy study (N = 1,850)
Population: 1,850 consecutive outpatients at 6 hospitals in 4 countries (2014–2016) with chest, abdominal or back pain, syncope or a perfusion deficit, in whom an acute aortic syndrome was in the differential diagnosis. ADD-RS was 0 in 438 patients (24%), 1 in 1,071 (58%) and above 1 in 341 (18%); 241 patients (13%) had an acute aortic syndrome (125 type A dissection, 53 type B dissection, 35 intramural haematoma, 18 aortic rupture, 10 penetrating ulcer). Final adjudication was by conclusive imaging, autopsy, surgery or 14-day follow-up.
Summary: ADvISED (Nazerian 2018): ADD-RS ≤1 plus negative D-dimer ruled out half of suspected patients and missed 3 of 924; D-dimer alone sensitivity 96.7% / specificity 64%
Result: A positive D-dimer (≥500 ng/mL) had sensitivity 96.7% (95% CI 93.6 to 98.6) and specificity 64% (95% CI 61.6 to 66.4) for acute aortic syndrome; 8 patients with the condition had a negative D-dimer. The ADD-RS = 0 / D-dimer-negative strategy applied to 294 patients with 1 case of acute aortic syndrome — failure rate 0.3% (95% CI 0.1 to 1.9), efficiency 15.9% (95% CI 14.3 to 17.6). The ADD-RS ≤1 / D-dimer-negative strategy applied to 924 patients with 3 cases — failure rate 0.3% (95% CI 0.1 to 1), efficiency 49.9% (95% CI 47.7 to 52.2).
Watch out: A single prospective study with a 13% disease prevalence — far higher than an unselected chest-pain population — so both the failure rate and the efficiency figures are spectrum-dependent; the 14-day follow-up component of adjudication can miss late-presenting cases.
Source: Nazerian P, Mueller C, Soeiro AM et al.. Diagnostic Accuracy of the Aortic Dissection Detection Risk Score Plus D-Dimer for Acute Aortic Syndromes: The ADvISED Prospective Multicenter Study. Circulation. 2018. PMID: 29030346. Registry ID: NCT02086136. MeSH: Acute Disease · Aged · Aortic Dissection · Aortic Aneurysm · Aortography · Biomarkers · Clinical Decision-Making · Computed Tomography Angiography · Decision Support Techniques · Diagnosis, Differential · Europe · Female · Fibrin Fibrinogen Degradation Products · Humans · Male · Middle Aged · Predictive Value of Tests · Prognosis · Prospective Studies · Reproducibility of Results · Syndrome