SourceMed · Shelf #9950 in the ask interface
Ranolazine in high-risk patients with implantable defibrillators (RAID, documented N = 1,012): the primary endpoint of ventricular tachycardia or fibrillation requiring device therapy, or death, was not significantly reduced (HR 0.84; p = 0.117; the treatment made no difference)
Shelf #9950 · Heart, vessels, blood pressure & clotting
NOT ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In high-risk patients with an implantable cardioverter-defibrillator and ischaemic or non-ischaemic cardiomyopathy, does ranolazine 1,000 mg twice daily, compared with placebo, reduce the first occurrence of ventricular tachycardia or fibrillation requiring appropriate device therapy, or death?
Balance of the evidence
NOT ESTABLISHED — Composition: 1 double-blind randomised trial (RAID, Zareba 2018) in 1,012 high-risk defibrillator patients — a documented base of 1,012 patients. This shelf is distinct from the live ranolazine shelf on angina symptoms in chronic coronary syndrome: a different population (defibrillator patients) and a different question (arrhythmia suppression, not angina). The primary endpoint (ventricular tachycardia or fibrillation requiring appropriate device therapy, or death) gave a hazard ratio of 0.84 (95% CI 0.67 to 1.05; p = 0.117; the treatment made no difference on the primary endpoint); 372 patients (37%) had a primary endpoint event, 270 (27%) had ventricular tachycardia or fibrillation, and 148 (15%) died. A prespecified secondary analysis found fewer recurrent ventricular tachycardia or fibrillation episodes requiring device therapy on ranolazine (HR 0.70, 95% CI 0.51 to 0.96; p = 0.028), and study-drug discontinuation was higher on ranolazine (49.6% versus 39.6%; p = 0.001). NOT ESTABLISHED: the primary endpoint was not met, and the trial was underpowered for it; the recurrent-event signal is secondary and does not establish the drug for this use.
MeSH: Aged · Cardiovascular Agents · Defibrillators, Implantable · Double-Blind Method · Female · Follow-Up Studies · Humans · Male · Middle Aged · Prospective Studies · Ranolazine · Risk Factors · Tachycardia, Ventricular · Ventricular Fibrillation
Cards (1)
Card 1 — RAID (Zareba 2018): ranolazine in 1,012 ICD patients — primary endpoint HR 0.84 (p = 0.117; the treatment made no difference); recurrent VT/VF therapies HR 0.70 in a secondary analysis
Study: Randomised controlled trial (N = 1,012)
Population: 1,012 high-risk patients with an implantable cardioverter-defibrillator and ischaemic or non-ischaemic cardiomyopathy, randomly assigned to ranolazine 1,000 mg twice daily (n = 510) or placebo (n = 502). Mean age 64 ± 10 years; 18% women. Follow-up was 28 ± 16 months.
Summary: RAID (Zareba 2018): ranolazine in 1,012 ICD patients — primary endpoint HR 0.84 (p = 0.117; the treatment made no difference); recurrent VT/VF therapies HR 0.70 in a secondary analysis
Result: The primary endpoint (ventricular tachycardia or ventricular fibrillation requiring appropriate implantable cardioverter-defibrillator therapy, or death) occurred in 372 patients (37%); the hazard ratio for ranolazine versus placebo was 0.84 (95% CI 0.67 to 1.05; p = 0.117). Overall, 270 patients (27%) had ventricular tachycardia or fibrillation and 148 (15%) died. In a prespecified secondary analysis, ranolazine patients had a lower risk of device therapies for recurrent ventricular tachycardia or fibrillation (hazard ratio 0.70, 95% CI 0.51 to 0.96; p = 0.028). No other prespecified secondary analyses — including inappropriate shocks, cardiac hospitalisations and quality of life — showed significant treatment effects. Blinded study drug was discontinued in 253 patients (49.6%) on ranolazine versus 199 (39.6%) on placebo (p = 0.001).
Watch out: The authors state the trial was underpowered for its primary endpoint, and nearly half of the ranolazine group stopped the study drug — the recurrent-event finding comes from a secondary analysis of a trial whose primary analysis was negative.
Source: Zareba W, Daubert JP, Beck CA et al.. Ranolazine in High-Risk Patients With Implanted Cardioverter-Defibrillators: The RAID Trial. Journal of the American College of Cardiology. 2018. PMID: 30071993. Registry ID: NCT01215253. MeSH: Aged · Cardiovascular Agents · Defibrillators, Implantable · Double-Blind Method · Female · Follow-Up Studies · Humans · Male · Middle Aged · Prospective Studies · Ranolazine · Risk Factors · Tachycardia, Ventricular · Ventricular Fibrillation