SourceMed · Shelf #996 in the ask interface

Spinal cord stimulation for chronic back and leg pain: HF10 and closed-loop

Shelf #996 · Brain, stroke & mind

POSSIBLE

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2015–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does 10-kHz high-frequency spinal cord stimulation relieve chronic back and leg pain better than traditional low-frequency stimulation — and does ECAP-controlled closed-loop stimulation beat open-loop on pain and function?

Balance of the evidence

POSSIBLE: Two randomised trials, each against an active stimulation comparator rather than sham, favoured the newer technology on responder rates: HF10 (10-kHz) beat traditional low-frequency stimulation in SENZA-RCT (back-pain responders 84.5% vs 43.8% at 3 months, sustained to 12 months), and ECAP-controlled closed-loop beat fixed-output open-loop in the double-blind Evoke trial (≥50% pain reduction 82.3% vs 60.3% at 3 months; 83.1% vs 61.0% at 12 months). The grade stops at POSSIBLE because both trials are industry-run device comparisons with a subjective responder endpoint, SENZA was unblinded (HF10 produces no paraesthesias, so patients could tell), and neither trial compares stimulation with no stimulation — the absolute value of any spinal cord stimulation is a different shelf's question.

MeSH: Back Pain/diagnosis,therapy · Chronic Pain/diagnosis,therapy · Leg/pathology · Pain Management/methods,standards · Spinal Cord Stimulation/methods,standards · Back Pain/therapy · Chronic Pain/therapy

Cards (3)

Card 1 — SENZA-RCT 2015: HF10 responders 84.5% for back pain versus 43.8% on traditional stimulation at 3 months, sustained to 12 months

Study: Randomised, parallel-arm, non-inferiority-designed controlled trial (superiority shown; 12 months)

Population: 198 subjects with both chronic back and leg pain randomised 1:1 across 10 US comprehensive pain treatment centres; 171 passed a temporary trial and were implanted with a spinal cord stimulation system. The abstract does not state mean age or sex mix.

Summary: SENZA-RCT 2015: HF10 responders 84.5% for back pain versus 43.8% on traditional stimulation at 3 months, sustained to 12 months.

Result: Responders (≥50% pain reduction with no stimulation-related neurological deficit) at 3 months: 84.5% of implanted HF10 subjects for back pain and 83.1% for leg pain, versus 43.8% and 55.5% for traditional low-frequency stimulation (P<0.001 for both comparisons). The relative ratio for responders was 1.9 (95% CI 1.4 to 2.5) for back pain and 1.5 (1.2 to 1.9) for leg pain — relative figures, the first inside the library's 0.5–2.0 caution band, printed here beside their absolute rates. Superiority was sustained through 12 months (P<0.001). HF10 subjects experienced no paraesthesias.

Watch out: Unblinded by design (paraesthesias reveal traditional stimulation), industry-conducted, and only patients who passed a temporary stimulation trial were implanted — responder rates apply to that screened population, not to all comers with back and leg pain.

Source: Kapural L et al. Novel 10-kHz High-frequency Therapy (HF10 Therapy) Is Superior to Traditional Low-frequency Spinal Cord Stimulation for the Treatment of Chronic Back and Leg Pain: The SENZA-RCT Randomized Controlled Trial. Anesthesiology. 2015 Oct;123(4):851-860. PMID: 26218762. Registry ID: none in the record's databank fields — the record carries no databank registration entry.

Card 2 — Evoke 2020: closed-loop stimulation beat open-loop — 82.3% versus 60.3% achieving ≥50% pain reduction at 3 months

Study: Multicentre, double-blind, parallel-arm, randomised controlled trial (3- and 12-month analyses)

Population: 134 patients with chronic, intractable back and leg pain (VAS ≥60 mm; Oswestry Disability Index 41–80), refractory to conservative therapy and new to spinal cord stimulation, at 13 US specialist clinics and hospitals, randomised 1:1 to ECAP-controlled closed-loop (67) or fixed-output open-loop (67) stimulation; the intention-to-treat analysis comprised 125 patients at 3 months and 118 at 12 months. The abstract does not state mean age or sex mix.

Summary: Evoke 2020: closed-loop stimulation beat open-loop — 82.3% versus 60.3% achieving ≥50% pain reduction at 3 months.

Result: The primary outcome (≥50% reduction in overall back and leg pain with no increase in pain medications) was achieved by more patients on closed-loop than open-loop at 3 months (51 [82.3%] of 62 vs 38 [60.3%] of 63; difference 21.9%, 95% CI 6.6 to 37.3; P=0.0052) and at 12 months (49 [83.1%] of 59 vs 36 [61.0%] of 59; difference 22.0%, 6.3 to 37.7; P=0.0060), meeting non-inferiority then superiority at both points. Safety profiles did not differ; the most frequent study-related adverse events in both groups were lead migration (9 patients [7%]), implantable pulse generator pocket pain (5 [4%]) and muscle spasm or cramp (3 [2%]).

Watch out: Double-blind — the stronger design of this shelf's two trials — but a single manufacturer's first pivotal trial of its own closed-loop system, with a responder endpoint and 12-month horizon; longer and independent replication is the missing piece.

Source: Mekhail N et al. Long-term safety and efficacy of closed-loop spinal cord stimulation to treat chronic back and leg pain (Evoke): a double-blind, randomised, controlled trial. Lancet Neurol. 2020 Feb;19(2):123-134. PMID: 31870766. Registry ID: ClinicalTrials.gov NCT02924129, from the record's databank fields.

Card 3 — Synthesis: newer stimulation beats older stimulation in both trials — against active comparators, not against nothing

Study: Synthesis

Population: Synthesis of the cards above: SENZA-RCT 2015 (171 implanted, HF10 vs traditional stimulation) and Evoke 2020 (134 randomised, closed-loop vs open-loop).

Summary: Newer stimulation beats older stimulation in both trials — against active comparators, not against nothing — POSSIBLE.

Result: Read together, the direction of travel in this technology is consistent: paresthesia-free high-frequency stimulation roughly doubled back-pain responder rates over traditional stimulation (84.5% vs 43.8%), and physiologically controlled closed-loop delivery added about 22 percentage points over open-loop (82.3% vs 60.3% at 3 months, held at 12 months). POSSIBLE, not LIKELY, because both comparisons are device-versus-device inside selected, trial-screened populations, and the pain outcome is self-reported in trials patients could partly see through. The drug, injection and surgical pain shelves do not test implanted stimulation and are not re-carded here.

Watch out: Do not quote SENZA's relative responder ratio (1.9) without its absolute rates, and do not use either trial to justify stimulation over conservative care — neither randomised that comparison.

Source: Synthesis of Kapural L et al. Anesthesiology. 2015;123(4):851-860. PMID: 26218762; Mekhail N et al. Lancet Neurol. 2020;19(2):123-134. PMID: 31870766. Registry IDs as on the individual cards.