SourceMed · Shelf #9975 in the ask interface

Bimatoprost sustained-release implant for open-angle glaucoma and ocular hypertension: both ARTEMIS phase 3 trials met noninferiority to twice-daily timolol drops through week 12 — but corneal endothelial cell loss grew with repeated implants (at least 20% loss in 10.2% on the 10-µg dose and 21.8% on the 15-µg dose after three administrations)

Shelf #9975 · Eyes, skin, nose & allergy

POSSIBLE (benefit)

Stamped: 2026-11-28.

Evidence published: 2020–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with open-angle glaucoma or ocular hypertension, does an intracameral bimatoprost sustained-release implant (10 or 15 µg, re-administered at weeks 16 and 32) lower intraocular pressure as well as twice-daily timolol drops — and what corneal price does repeated implantation carry?

Balance of the evidence

POSSIBLE (benefit) — Composition: 2 independent phase 3 randomised trials of the same implant programme (ARTEMIS 1, 594 patients; Medeiros 2020 — and ARTEMIS 2, 528 patients; Bacharach 2021) — a documented base of 1,122 patients. Both trials met noninferiority to timolol through week 12 after each administration, and about four in five implant patients needed no further pressure-lowering treatment for a year after the third implant. The counterweight is corneal: endothelial cell loss and corneal adverse events rose with dose and with repeated administration, which is why the marketed single-administration use is narrower than the trial regimen. The fences: live #609 homes laser trabeculoplasty versus drops, live #4023 homes the newer drops (netarsudil, latanoprostene bunod) and live #6426 homes the XEN gel stent versus trabeculectomy — this shelf is the bimatoprost implant only. POSSIBLE (benefit): pressure lowering equal to drops with a drop-free year for most, bought with a cumulative corneal risk that caps how the implant can be used.

MeSH: Adult · Aged · Aged, 80 and over · Antihypertensive Agents · Bimatoprost · Double-Blind Method · Drug Implants · Female · Glaucoma, Open-Angle · Humans · Intraocular Pressure · Male · Middle Aged · Ocular Hypertension · Timolol · Tonometry, Ocular · Vitreous Body · Young Adult · Dose-Response Relationship, Drug · Ophthalmic Solutions

Cards (2)

Card 1 — ARTEMIS 1: both implant doses noninferior to timolol through week 12 — but at least 20% corneal endothelial loss in 10.2% (10 µg) and 21.8% (15 µg) after three implants

Study: Phase 3 randomised controlled trial (N = 594)

Population: Randomised, masked, 20-month phase 3 trial in 594 adults with open-angle glaucoma or ocular hypertension (198 per arm): bimatoprost implant 10 µg or 15 µg on day 1 with re-administration at weeks 16 and 32, versus twice-daily topical timolol maleate 0.5%; baseline hour-0 intraocular pressure 22–32 mmHg after washout.

Summary: ARTEMIS 1: both implant doses noninferior to timolol through week 12 — but at least 20% corneal endothelial loss in 10.2% (10 µg) and 21.8% (15 µg) after three implants

Result: Both doses were noninferior to timolol after each administration. Mean diurnal pressure fell from 24.0, 24.2 and 23.9 mmHg at baseline to ranges of 16.5–17.2 (10 µg), 16.5–17.0 (15 µg) and 17.1–17.5 mmHg (timolol) through week 12. Corneal and inflammatory adverse events of interest were more frequent with the implant and highest at 15 µg; after three administrations at fixed 16-week intervals, at least 20% corneal endothelial cell density loss occurred in 10.2% (10 µg) and 21.8% (15 µg). Three implant-treated patients with corneal events had more than a 2-line acuity loss at their last visit.

Watch out: The trial's fixed three-implant regimen is not the approved single-administration use: the endothelial-loss figures belong to repeated implantation and should not be read as the risk of one implant — nor should one implant be assumed to last as the three-implant course did.

Source: Medeiros FA, Walters TR, Kolko M, Coote M, Bejanian M et al.. Phase 3, Randomized, 20-Month Study of Bimatoprost Implant in Open-Angle Glaucoma and Ocular Hypertension (ARTEMIS 1). Ophthalmology. 2020. PMID: 32544560. Registry ID: not stated in the record. MeSH: Adult · Aged · Aged, 80 and over · Antihypertensive Agents · Bimatoprost · Double-Blind Method · Drug Implants · Female · Glaucoma, Open-Angle · Humans · Intraocular Pressure · Male · Middle Aged · Ocular Hypertension · Timolol · Tonometry, Ocular · Vitreous Body · Young Adult

Card 2 — ARTEMIS 2: pressure reductions 6.2–7.8 mmHg on implant versus 6.1–6.7 mmHg on timolol; 77.5–79.0% needed no further treatment for a year after the third implant

Study: Phase 3 randomised controlled trial (N = 528)

Population: Randomised, masked, 20-month phase 3 trial in 528 adults with open-angle glaucoma or ocular hypertension and an open inferior iridocorneal angle: bimatoprost implant 10 or 15 µg on day 1, week 16 and week 32, versus twice-daily topical timolol maleate 0.5%.

Summary: ARTEMIS 2: pressure reductions 6.2–7.8 mmHg on implant versus 6.1–6.7 mmHg on timolol; 77.5–79.0% needed no further treatment for a year after the third implant

Result: Both doses met noninferiority to timolol through week 12; mean pressure reductions from baseline ranged 6.2–7.4 mmHg (10 µg), 6.5–7.8 mmHg (15 µg) and 6.1–6.7 mmHg (timolol), with similar lowering after the second and third administrations. The probability of requiring no further pressure-lowering treatment for 1 year after the third administration was 77.5% (10 µg) and 79.0% (15 µg). The commonest adverse event was conjunctival hyperaemia around administration; corneal events were more frequent at 15 µg, and mean endothelial cell density loss to month 20 was about 5% in 10-µg eyes versus about 1% on timolol.

Watch out: Noninferiority to timolol — a mid-potency drop — is the claim, not superiority to modern prostaglandin drops; and the drop-free year follows three implants, the regimen the corneal data argue against repeating.

Source: Bacharach J, Tatham A, Ferguson G, Belalcázar S, Thieme H et al.. Phase 3, Randomized, 20-Month Study of the Efficacy and Safety of Bimatoprost Implant in Patients with Open-Angle Glaucoma and Ocular Hypertension (ARTEMIS 2). Drugs. 2021. PMID: 34724172. Registry ID: not stated in the record. MeSH: Adult · Aged · Aged, 80 and over · Antihypertensive Agents · Bimatoprost · Dose-Response Relationship, Drug · Double-Blind Method · Drug Implants · Female · Glaucoma, Open-Angle · Humans · Intraocular Pressure · Male · Middle Aged · Ocular Hypertension · Ophthalmic Solutions · Timolol · Young Adult