SourceMed · Shelf #9976 in the ask interface
Stapes prosthesis choice in otosclerosis: a 0.6-mm piston beat 0.4 mm on success in the controlled studies (67% versus 58% with the air-bone gap closed within 10 dB; 81.1% versus 75.1% in 9,536 pooled cases), and Nitinol heat-crimping prostheses beat other materials on the same endpoint (odds ratio 2.56, 7 observational studies, 1,385 patients)
Shelf #9976 · Eyes, skin, nose & allergy
POSSIBLE (benefit)
Stamped: 2026-11-28.
Evidence published: 2011–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients undergoing stapedotomy for otosclerosis, do prosthesis diameter (0.6 mm versus 0.4 mm) and prosthesis material (Nitinol heat-crimping versus other prostheses) change postoperative hearing — the share of patients closing the air-bone gap to within 10 dB, and the size of the residual gap?
Balance of the evidence
POSSIBLE (benefit) — Composition: 2 systematic reviews with meta-analysis of observational stapes-surgery studies (Laske 2011, prosthesis diameter: 5 controlled studies, 590 patients, plus 9,536 pooled cases in 62 further studies; Reis 2018, Nitinol versus non-Nitinol prostheses: 7 studies, 1,385 patients) — the pools come from overlapping eras of the same surgical literature and are not added; the documented base is stated per pool on the cards. There are no randomised trials of prosthesis choice; both syntheses rest on non-randomised comparisons, which is why the stamp is POSSIBLE despite consistent direction. A companion question — endoscopic versus microscopic stapes surgery — is homed separately on shelf #9977. POSSIBLE (benefit): wider (0.6-mm) pistons and Nitinol prostheses are each associated with better gap closure in the observational record, with surgeon and era effects impossible to strip out.
MeSH: Audiometry, Pure-Tone · Auditory Threshold · Bone Conduction · Humans · Ossicular Prosthesis · Otosclerosis · Prosthesis Implantation · Stapes Surgery · Treatment Outcome · Alloys · Observational Studies as Topic · Prosthesis Design
Cards (2)
Card 1 — Prosthesis diameter: 0.6 mm beat 0.4 mm — success 67% versus 58% in the controlled studies, 81.1% versus 75.1% across 9,536 pooled cases
Study: Systematic review and meta-analysis (5 controlled studies, N = 590; pooled subgroups, 9,536 cases)
Population: Systematic review and meta-analysis of stapedotomy without interposition for otosclerosis: 5 controlled studies directly comparing prosthesis diameters (590 patients) for the formal meta-analysis, plus 62 further studies whose comparable subgroups (9,536 cases in total) were pooled by diameter (0.3–0.8 mm).
Summary: Prosthesis diameter: 0.6 mm beat 0.4 mm — success 67% versus 58% in the controlled studies, 81.1% versus 75.1% across 9,536 pooled cases
Result: In the 5 controlled studies, success (air-bone gap closed within 10 dB) favoured 0.6-mm over 0.4-mm prostheses, 67% versus 58% (p = 0.05). In the pooled data the 0.6-mm prosthesis again did better: postoperative air conduction threshold 29 dB versus 35 dB, postoperative air-bone gap 7 dB versus 11 dB, gap improvement 25 dB versus 21 dB, and success rate 81.1% versus 75.1% (all p < 0.001). Frequency-specific gap analysis showed no advantage at every frequency, as reported in the record.
Watch out: The large pooled analysis mixes decades, surgeons and techniques, and diameter choice is not random — surgeons pick piston size for the anatomy in front of them, so part of the 0.6-mm advantage may be case selection rather than the piston.
Source: Laske RD, Röösli C, Chatzimichalis MV, Sim JH, Huber AM et al.. The influence of prosthesis diameter in stapes surgery: a meta-analysis and systematic review of the literature. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2011. PMID: 21765384. Registry ID: not stated in the record. MeSH: Audiometry, Pure-Tone · Auditory Threshold · Bone Conduction · Humans · Ossicular Prosthesis · Otosclerosis · Prosthesis Implantation · Stapes Surgery · Treatment Outcome
Card 2 — Nitinol versus other prostheses: odds of closing the air-bone gap to 10 dB or less were 2.56 times higher with Nitinol (7 studies, 1,385 patients)
Study: Systematic review and meta-analysis of observational studies (7 studies, N = 1,385)
Population: Systematic review and meta-analysis of observational studies of primary stapes surgery for otosclerosis comparing the Nitinol heat-crimping prosthesis (637 patients) with other stapedotomy prostheses (748 patients) — 7 eligible studies, 1,385 patients in total, using American Academy of Otolaryngology–Head and Neck Surgery audiometry reporting guidelines.
Summary: Nitinol versus other prostheses: odds of closing the air-bone gap to 10 dB or less were 2.56 times higher with Nitinol (7 studies, 1,385 patients)
Result: Effectiveness (postoperative air-bone gap of 10 dB or less) was significantly higher with Nitinol prostheses: combined odds ratio 2.56 (95% CI 1.38 to 4.76; p = 0.003). Mean preoperative age did not differ significantly between the Nitinol and non-Nitinol groups (p = 0.931).
Watch out: Seven observational studies with a wide confidence interval: Nitinol prostheses are also the newer device, so era, surgeon experience and reporting-guideline adoption all lean in the same direction as the apparent material advantage.
Source: Reis LR, Donato M, Almeida G, Castelhano L, Escada P et al.. Nitinol versus non-Nitinol prostheses in otosclerosis surgery: a meta-analysis. Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale. 2018. PMID: 30197420. Registry ID: not stated in the record. MeSH: Alloys · Humans · Observational Studies as Topic · Ossicular Prosthesis · Otosclerosis · Prosthesis Design · Stapes Surgery