SourceMed · Shelf #9992 in the ask interface

Rapid intrapartum tests for group B streptococcus colonisation against culture: PCR is accurate (sensitivity 94.1% / specificity 99.3% in a 177-woman cohort, result within the hour) while a rapid immunoassay is not (sensitivity 57.1% / specificity 83.2%) — and the 29-study synthesis behind the field was of generally poor quality

Shelf #9992 · Women’s health

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2006–2026.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In women in labour, how accurately do rapid intrapartum tests — real-time PCR and rapid immunoassays — detect group B streptococcus colonisation against intrapartum culture, and how fast are they?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: a systematic review of 29 test-accuracy studies in 15,691 labouring women (Honest 2006), a 177-woman retrospective accuracy cohort for a rapid PCR assay (Bröcking 2026) and a 195-woman prospective cohort for a rapid immunochromatographic assay (Delabaere 2017). Sensitivity and specificity are labelled in words at first occurrence: the PCR assay (Xpert Xpress GBS, as named in the record) reached sensitivity 94.1% (95% CI 80.3 to 99.3) / specificity 99.3% (96.2 to 100.0) against culture on the same rectovaginal swab, with results within 1 hour against culture's 24–48 hours (Bröcking 2026). The immunoassay (DIMA test, as named in the record) reached only sensitivity 57.1% / specificity 83.2% against intrapartum culture — better sensitivity than the 42.9% of antenatal screening culture, but at much lower specificity than antenatal culture's 97% (Delabaere 2017). Across six test types the synthesis found real-time PCR the most accurate rapid test (about 40 minutes) and optical immunoassay the fastest (about 30 minutes), but judged the methodologic quality of the 29 studies generally poor (Honest 2006). MEASUREMENT ACCURACY — PARTIAL: the grade is split by technology — PCR performs at near-culture accuracy within the hour, immunoassay does not, and the older synthesis base is weak.

MeSH: Adult · Anti-Bacterial Agents · Antibiotic Prophylaxis · Carrier State · Early Diagnosis · Female · France · Humans · Immunoassay · Immunoenzyme Techniques · Immunologic Tests · Infant, Newborn · Infant, Newborn, Diseases · Infectious Disease Transmission, Vertical · Labor, Obstetric · Latex Fixation Tests · Mass Screening · Netherlands · Parturition · Polymerase Chain Reaction · Predictive Value of Tests · Pregnancy · Pregnancy Complications, Infectious · Retrospective Studies · Sensitivity and Specificity · Streptococcal Infections · Streptococcus agalactiae · Time Factors · Vagina

Cards (3)

Card 1 — Rapid PCR vs culture on the same swab: sensitivity 94.1% / specificity 99.3%, result within 1 hour (Bröcking 2026)

Study: Retrospective diagnostic-accuracy cohort (N = 177)

Population: 177 women at a Dutch secondary-care teaching hospital (February–September 2024) who had both intrapartum PCR (Xpert Xpress GBS — as named in the record) and intrapartum culture on the same rectovaginal swab, tested because of predefined clinical risk factors under the Dutch risk-based protocol.

Summary: Rapid PCR vs culture on the same swab: sensitivity 94.1% / specificity 99.3%, result within 1 hour (Bröcking 2026)

Result: Sensitivity and specificity of the PCR assay against culture were sensitivity 94.1% (95% CI 80.3 to 99.3) / specificity 99.3% (95% CI 96.2 to 100.0). Of 33 PCR-positive women, 28 (85%) received intrapartum antibiotic prophylaxis; non-treatment was due to rapid labour progression. PCR returns results within 1 hour, against 24–48 hours for standard culture.

Watch out: A risk-selected (not universal-screening) single-centre cohort with only 34 culture-positive women behind the sensitivity estimate — the confidence interval runs from 80.3% to 99.3%.

Source: Bröcking MAM, Nahuis MJ, Rozemeijer W et al.. Rapid intrapartum PCR assay for group B streptococcus within a dutch risk-based strategy: diagnostic accuracy and optimization of antibiotic use in a single-centre cohort. European journal of obstetrics, gynecology, and reproductive biology. 2026. PMID: 42575022. Registry ID: not stated in the record. MeSH: Humans · Female · Streptococcal Infections · Streptococcus agalactiae · Pregnancy · Netherlands · Retrospective Studies · Pregnancy Complications, Infectious · Polymerase Chain Reaction · Antibiotic Prophylaxis · Adult · Anti-Bacterial Agents · Sensitivity and Specificity

Card 2 — Rapid immunoassay (DIMA): sensitivity 57.1% / specificity 83.2% — misses over two in five carriers (Delabaere 2017)

Study: Prospective diagnostic-accuracy cohort (N = 195)

Population: 195 pregnant women presenting in full-term labour at a single French site (June–August 2012), each tested with the intrapartum DIMA immunochromatographic assay (as named in the record), intrapartum culture and their prenatal screening culture at 35–38 weeks.

Summary: Rapid immunoassay (DIMA): sensitivity 57.1% / specificity 83.2% — misses over two in five carriers (Delabaere 2017)

Result: Against intrapartum culture, the DIMA test's sensitivity was 57.1% and its specificity 83.2%. The comparison prenatal screening culture achieved sensitivity 42.9% and specificity 97% against the same intrapartum reference. The authors judge the immunoassay's performance inferior to that reported for rapid PCR assays.

Watch out: One centre and one summer: colonisation prevalence and spectrum are local, and a 57% sensitivity means the test cannot rule out carriage — its role, if any, is different from PCR's.

Source: Delabaere A, Curinier S, Ughetto S et al.. Accuracy of a rapid intrapartum group B Streptococcus test: A new immunochromatographic assay. Journal of gynecology obstetrics and human reproduction. 2017. PMID: 28934088. Registry ID: not stated in the record. MeSH: Early Diagnosis · Female · France · Humans · Immunoassay · Infant, Newborn · Infant, Newborn, Diseases · Infectious Disease Transmission, Vertical · Labor, Obstetric · Mass Screening · Parturition · Polymerase Chain Reaction · Predictive Value of Tests · Pregnancy · Pregnancy Complications, Infectious · Sensitivity and Specificity · Streptococcal Infections · Streptococcus agalactiae · Time Factors · Vagina

Card 3 — 29 studies, 15,691 women: PCR most accurate, immunoassay fastest, study quality generally poor (Honest 2006)

Study: Systematic review of test-accuracy studies (29 studies, 15,691 women)

Population: Systematic review of 29 intrapartum test-accuracy studies in 15,691 labouring women, evaluating 6 tests — PCR, optical immunoassay, DNA hybridisation, enzyme immunoassay, latex agglutination and Islam starch medium — each confirmed against laboratory culture.

Summary: 29 studies, 15,691 women: PCR most accurate, immunoassay fastest, study quality generally poor (Honest 2006)

Result: Real-time PCR was the most accurate of the rapid tests and took 40 minutes to complete; the optical immunoassay took 30 minutes. Likelihood ratios were pooled within test subgroups, but the review's abstract does not print a single pooled sensitivity/specificity pair, so none is quoted here. The methodologic quality of the included studies was generally poor, and the authors require a robust technology assessment of accuracy, acceptability and cost-effectiveness before implementation.

Watch out: Single-synthesis flag: this 2006 review is the field's synthesis base and predates the current commercial PCR platforms — it supports the technology ranking, not today's assay-specific numbers.

Source: Honest H, Sharma S, Khan KS et al.. Rapid tests for group B Streptococcus colonization in laboring women: a systematic review. Pediatrics. 2006. PMID: 16585299. Registry ID: not stated in the record. MeSH: Adult · Carrier State · Female · Humans · Immunoassay · Immunoenzyme Techniques · Immunologic Tests · Labor, Obstetric · Latex Fixation Tests · Polymerase Chain Reaction · Pregnancy · Pregnancy Complications, Infectious · Sensitivity and Specificity · Streptococcal Infections · Streptococcus agalactiae · Vagina