SourceMed · Shelf #9999 in the ask interface
Diagnosing coeliac disease in children without a biopsy: tissue-transglutaminase IgA at 10 times the upper limit of normal, plus a positive endomysium antibody test and a symptom, gave a positive predictive value of 99.75% in a 707-child prospective study
Shelf #9999 · Liver & gut
PREDICTIVE PERFORMANCE — HIGH
Stamped: 2026-11-28.
Evidence published: 2017.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In children being tested for coeliac disease on a gluten-containing diet, how accurately does the no-biopsy pathway — tissue-transglutaminase IgA at least 10-fold the upper limit of normal, confirmed by endomysium antibodies (with or without HLA-DQ2/DQ8 testing) — identify coeliac disease against biopsy-based diagnosis?
Balance of the evidence
PREDICTIVE PERFORMANCE — HIGH — Composition: one large international prospective accuracy study (Werkstetter 2017): 803 children recruited at 33 paediatric gastroenterology units in 21 countries, 707 analysed (645 diagnosed with coeliac disease, 46 without, 16 inconclusive). Diagnosis first: every child entered with a positive tissue-transglutaminase IgA (TGA-IgA) test on a gluten-containing diet, and final diagnoses were built from local and central serology, HLA testing and reference-pathologist histology, so this study validates the pathway in test-positive children rather than screening unselected children. The guideline pathway — local TGA-IgA at least 10-fold the upper limit of normal, a positive endomysium antibody (EMA) test, and any symptom — identified coeliac disease in 399 children with a positive predictive value of 99.75% (95% CI 98.61 to 99.99); restricting 'symptom' to malabsorption features (278 children) gave a positive predictive value of 100.00% (95% CI 98.68 to 100.00). Adding HLA-DQ2/DQ8 testing did not increase accuracy. Central-laboratory results agreed at high antibody levels (positive predictive values 99.63% to 100.00% across assays at 10-fold or more) but differed greatly at lower levels, so the pathway's accuracy is a property of the high threshold, not of TGA-IgA positivity in general. Positive predictive value is labelled in words here because it, not a sensitivity/specificity pair, is the study's primary accuracy measure. PREDICTIVE PERFORMANCE — HIGH: at the 10-fold threshold with EMA confirmation, a no-biopsy diagnosis was wrong in at most a handful per thousand in this prospective practice-based study.
MeSH: Adolescent · Autoantibodies · Biomarkers · Biopsy · Celiac Disease · Child · Child, Preschool · Europe · Female · GTP-Binding Proteins · HLA-DQ Antigens · Humans · Immunoglobulin A · Infant · Intestine, Small · Male · Middle East · Molecular Diagnostic Techniques · Predictive Value of Tests · Prognosis · Prospective Studies · Protein Glutamine gamma Glutamyltransferase 2 · Reproducibility of Results · Serologic Tests · Transglutaminases
Cards (1)
Card 1 — No-biopsy pathway: positive predictive value 99.75% (399 children) at TGA-IgA ≥10× the upper limit plus positive EMA and a symptom (Werkstetter 2017)
Study: Prospective multicentre diagnostic-accuracy study (N = 707 analysed)
Population: 707 children (65.1% girls, median age 6.2 years) on a gluten-containing diet who had tested positive for TGA-IgA and were seen at 33 paediatric gastroenterology units in 21 countries (803 recruited; 96 excluded for incomplete data, low IgA or poor-quality biopsies); 645 were finally diagnosed with coeliac disease, 46 without, and 16 inconclusive (counted as not having coeliac disease for accuracy calculations).
Summary: No-biopsy pathway: positive predictive value 99.75% (399 children) at TGA-IgA ≥10× the upper limit plus positive EMA and a symptom (Werkstetter 2017)
Result: Children meeting the European guideline criteria in local laboratories — TGA-IgA at least 10-fold the upper limit of normal, a positive endomysium antibody test, and any symptom (n = 399) — had coeliac disease with a positive predictive value of 99.75% (95% CI 98.61 to 99.99); with malabsorption symptoms only (n = 278) the positive predictive value was 100.00% (95% CI 98.68 to 100.00). HLA-DQ2/DQ8 analysis did not increase accuracy. Across 16 central antibody assays, positive predictive values at the 10-fold threshold ranged from 99.63% to 100.00%, while results at lower antibody levels differed greatly between assays.
Watch out: Only 46 children in the analysis did not have coeliac disease, and all entrants were already TGA-IgA-positive referrals — the near-perfect predictive value applies to that enriched population and high threshold, not to low-positive results or population screening.
Source: Werkstetter KJ, Korponay-Szabó IR, Popp A et al. Accuracy in Diagnosis of Celiac Disease Without Biopsies in Clinical Practice. Gastroenterology. 2017. PMID: 28624578. Registry ID: not stated in the record. MeSH: Adolescent · Autoantibodies · Biomarkers · Biopsy · Celiac Disease · Child · Child, Preschool · Europe · Female · GTP-Binding Proteins · HLA-DQ Antigens · Humans · Immunoglobulin A · Infant · Intestine, Small · Male · Middle East · Molecular Diagnostic Techniques · Predictive Value of Tests · Prognosis · Prospective Studies · Protein Glutamine gamma Glutamyltransferase 2 · Reproducibility of Results · Serologic Tests · Transglutaminases